手機號: CS-826
銷售組織: | Piece/Pieces |
The file is encrypted. Please fill in the following information to continue accessing it
CS-826是台式分光光度計,用於顏色測量,具有高精度和一致性。先進的技術和功能強大的數據處理器可在黑色對象的顏色測量中獲得CS-826的出色穩定性;儀器的自動校準確保長期測量穩定性;改進的高穩定性紫外線光源可提供穩定的熒光測量標記,並且儀器測量數據可以與美國,日本和歐洲其他競爭產品保持良好的一致性。
*在黑色物體上測量時具有出色的穩定性
*它與美國,日本和歐洲的其他競爭產品具有良好的一致性
*高穩定性紫外線光源提供穩定的熒光測量標記
*自動校準熒光校準功能使測量熒光材料更為準確
*短期可重複性:δE*AB0。在01之內
*長期可重複性:δE*AB0。在01之內
產品功能
*自動校準
*高穩定性紫外線源,提供穩定的熒光測量結果
*在黑色樣品上測量時出色的可重複性
*與美國,日本和歐洲生產的其他競爭產品一致性
*出色的長期可重複性,即使在環境快速變化之後仍然可以保證出色的可重複性
*24種照明劑和40多種測量指數
*溫度和濕度補償功能
*七英寸觸摸屏,Android操作系統
*雙光路頻譜分析技術
*支持SCI+SCE同時快速測量
*它有兩個燈:脈衝氙氣和LED
Model | CS-826 |
Illumination/ Viewing System | Reflectance: d/8(Diffused illumination, 8 degree viewing) Simultaneous measurement of SCI/SCE, conform to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, DIN5033 Teil7, JIS Z8722 condition C, ASTM E1164,ASTM-D1003-07 Transmittance d/0(Diffused illumination, 0 degree viewing ) |
Sensor | Dual column high precision CMOS array sensor |
Grating method | Concave grating |
Sphere diameter | 152mm |
Wavelength range | 360nm-780nm |
Wavelength interval | 10nm |
Half wave width
|
1nm |
Reflectance range resolution
|
0-200%, resolution 0.01% |
Lighting source
|
Pulsed xenon lamp and LED |
UV
|
Including UV, 400nm cut-off, 420nm cut-off and 460nm cut-off |
Test time | SCI or SCE mode < 2 seconds, SCI + SCE simultaneous measurement < 4 seconds |
Test aperture | Reflection: xlav Φ 25.4mm/ Φ 30mm LAV Φ 15mm/ Φ 18mm MAV Φ 8mm/ Φ 11mm SAV Φ 3mm/ Φ 6mm The user can customize the caliber, and the caliber switch automatically identifies thetransmission: Φ 17mm/ Φ 25mm |
Transmission measurement specification
|
Sample width and height: unlimited, thickness: ≤ 50mm |
Long term repeatability |
Xlav chromaticity value: standard deviation Δ E * AB within 0.015
(for any temperature change of 20 ºC± 10 ºC, measure the white correction plate every hour within 24 hours) |
Repeatability |
Δ E*ab≤0.01,
Spectral reflectance / transmittance ≤ 0.1% |
Inter-instrument difference |
XLAV Δ E * AB 0.2 (based on the average value of 12 color plates of BCRA series at 23 ° C)
|
Observer | 2 ° standard observer and 10 ° standard observer |
Light source
|
A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84 |
Language | Simplified Chinese, Spanish, Spanish, Spanish, Portuguese, Portuguese |
Display
|
Spectral data, spectrogram, chroma data, color difference data, color difference diagram, pass / fail judgment, simulated color, color evaluation, haze, liquid chroma, color bias |
Color space | L*a*b,L*C*h,Hunter Lab,Yxy,XYZ |
Color index | WI(ASTM E313-00,ASTM E313-73,CIE/ISO,AATCC,Hunter,Taube,Berger Stensby), YI(ASTMD1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),Metamerism index milm, color fastness, color fastness,ISO brightness, R457, a density, t density, e density, m density, APHA / Hazen / Pt Co, Gardner index,Saybolt index, ASTM Color, haze, total transmittance, hiding power, force, strength |
Colour-difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc,ΔE*94,ΔE*00,ΔEab(Hunter),555 hue classification |
Storage space | 8GB |
Screen | 7 inch capacitive touch screen |
Operating system | Android |
Supply | DC regulated power supply |
Working temperature and humidity range |
5 ~ 40 ° C, relative humidity below 80% (at 35 ° C), no condensation |
Storage temperature and humidity range |
-20 ~ 45 ° C, relative humidity below 80% (at 35 ° C), no condensation |
Accessories | Power adapter, data cable, transmission fixture, software USB flash disk, black cavity, white board,green board, 0% calibration shading cover (attached to 820n)30mm diameter plate, 18mm diameter plate, 11mm diameter plate, 6mm diameter plate, support table, cuvette, damping handle |
Optional Accessories | Heating transmission fixture (including control circuit), vertical support, pneumatic ejector rod(including control circuit), small sample clamping accessories, European standard plugReflective cuvette support, corrosion-resistant protective plate (non removable), fiber test box,film clamp, micro transmission clamp, pull rod box and American standard plug |
Interface | RS-232,USB,USB-B |
Other | 1. Camera viewfinder positioning; 2. The instrument can measure laterally, upward and downward (using accessories); 3. Automatic temperature and humidity compensation function |
HS編碼: 9027300090